TECHNICAL SPECIFICATIONS FOR INCINERATOR– 50 KGS/HR

1. Brand Type & Model,Indicate
•Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The majority of the wastes will be of bio medical nature, with up to 70% by volume of medical wastes and up to 30% by volume of hazardous and or general wastes. The content of the combustible matter will be above 60% and moisture content below 35%. The wastes will be crudely pre-mixed by selective loading from different waste streams prior to incinerator loading.

•An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading. The automated burn completion and cool down cycle will take place overnight for the incinerator.

•The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.

•Also consider provision for meeting international emission standards and have a thermal efficiency of not less than 85%.

2. Type of Waste,Health care waste
3. Burning Capacity,50 kgs/hr
4. Auxiliary Fuel,Diesel
5. Type of Burner Operation,fully automatic burners
6. Number of operation hours,Nominally 8hours/Day 310 Days/Annum(Up
, To 14hrs/Day
7. Temperature,
Primary Chamber 800-10000C
Secondary Chamber,850-16000C
,
8.Ambient operating condition,-5-500C
9.Maximum Noise Level,82 d B (A) 1m
10.Moisture content,20-50%
PRIMARY CHAMBER,


Tel: +86-25-8461 0201

Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Leave a comment